Quick Facts

  • 4 lasers, 14 parameters*
  • 405, 488, 561, 640 nm lasers
  • Plate-reading capacity (96 and 384 well)
  • Accepts conical, round, or flat bottom plates

* includes FSC and SSC in addition to colors

Location: Biotech 140 and Veterinary Research Tower TB-016


Technical Specifications

The Thermo Fisher Attune NxT is a compact, efficient, and flexible benchtop analyzer that utilizes acoustic-assisted hydrodynamic focusing. This enables faster sample throughput rates and minimizes clogs, and allows a broad range of cell and sample types. In addition, the Attune NxT has a positive-displacement syringe pump system for sample delivery, allowing volumetric analysis. The Attune NxT software is intuitive and easy to learn, and prompts users with step-by-step instructions for cleaning cycles and shutdown procedures. With the autosampler attachment and optional passive cooling system, the Attune can run large numbers of low volume samples in plate format.

Excitation lasers405 nm, 488 nm, 561nm, 638 nm
Output power405 nm, 488 nm, 561 nm (100 mW), 638 nm (140 mW)
Detection parameters14 fluorescence + 2 scatter
Sample tubeSingle, manual loaded tube or plate autosampler
Tube types0.5 -mL, 1.5 mL, and 5-mL tubes
Plate types96- and 384-well conical, round, or flat bottom plates

Instrument Configuration

LaserChannel LabelFilter BPFilter LPPreferred Colors
405VL1450/50410Brilliant Violet 421
VL2525/50495Brilliant Violet 480
VL3610/20555Brilliant Violet 605
VL4660/20Brilliant Violet 650
VL5710/50680Brilliant Violet 711
VL6780/60740Brilliant Violet 786
488BL1530/30503Alexa Fluor 488, GFP, FITC
BL2695/40555PerCP-Cy5.5, PerCP
561YL1586/16PE
YL2620/15577PE-Dazzle 594, PE-Texas Red
YL3780/60650PE-Cy7
637RL1670/14654APC
RL2720/30690Alexa Fluor 700
RL3780/60740APC-Cy7

Saving Your Data

Users are given access to a fileshare drive to save data after being trained on the instrument. You can save your data as experiment files, FCS files, and PDFs.

Experiment File:

1.Right-click the experiment name -> Export -> Experiment (plate experiments will say Plate)
2. Save to This PC -> FlowCyto Share X:\ drive -> Your folder -> Create new folder with today’s date.
For tube experiment, this will be .atx, for plate experiments this will be .apx file.

FCS Files:

1. Right-click the experiment name -> Export -> FCS files.
2. Save to This PC -> FlowCyto Share X:\ drive under your folder.
3. If a popup message asks if you want to Update Keywords, we do recommend selecting the
checkbox at the bottom to select all, then choose Update Keywords.

PDFs:

1. Tube experiments: Right-click the experiment name -> Print.
Plate experiments: Right-click the Group name -> Print
2. Select what workspace(s) to print -> OK -> OK
3. Save to This PC -> FlowCyto Share X:\, your folder, Save.

Don’t forget: Saving your data is your responsibility. We regularly delete experiments from our instrument’s computers to free up memory.


Instrument Pricing