New publication: Capture of circulating tumor cells from whole blood of prostate cancer patients using geometrically enhanced differential immunocapture (GEDI) and a prostate-specific antibody

Capture of circulating tumor cells from whole blood of prostate cancer patients using geometrically enhanced differential immunocapture (GEDI) and a prostate-specific antibody

Jason P. Gleghorn ,  Erica D. Pratt ,  Denise Denning ,  He Liu ,  Neil H. Bander ,  Scott T. Tagawa ,  David M. Nanus ,  Paraskevi A. Giannakakou and Brian J. Kirby

Lab Chip, 2010,10, 27-29, DOI: 10.1039/B917959C
Abstract

Geometrically enhanced differential immunocapture (GEDI) and an antibody for prostate-specific membrane antigen (PSMA) are used for high-efficiency and high-purity capture of prostate circulating tumor cells from peripheral whole blood samples of castrate-resistant prostate cancer patients.

Graphical abstract: Capture of circulating tumor cells from whole blood of prostate cancer patients using geometrically enhanced differential immunocapture (GEDI) and a prostate-specific antibody